Alex acc7060be6 fix(wireplumber): guard async callbacks by connection generation; wire scroll once
Addresses review on #5168:

- Generational aliasing (blocking): setupConnection()/onReconnectTimeout()
  rebuild wp_core_/om_/pending_plugins_ in place on the same self, but the
  async load/activate callbacks carried no generation, and isModuleAlive()
  only proves self still exists. If PipeWire dropped again while a previous
  connection's async chain was still in flight, a stale completion would run
  against the rebuilt connection (a stray --pending_plugins_, an out-of-order
  install_object_manager), re-creating #2882's stale/blank state. Each async
  call now carries an AsyncCall{self, generation}; connection_generation_ is
  bumped in setupConnection(), and every callback drops out when its
  generation no longer matches (checked after isModuleAlive short-circuits).

- Duplicate scroll handlers: onMixerApiLoaded re-runs on every reconnect and
  connected a new scroll handler each time (dead but accumulating). Moved the
  one-time wiring to the constructor; handleScroll no-ops while mixer_api_ is
  null, so wiring it before the first connect is safe.
2026-07-05 09:53:11 +02:00
..
2026-02-04 09:24:14 +01:00
2026-03-30 14:25:41 -07:00
2026-07-04 01:42:35 +02:00
2023-10-15 17:52:12 -03:00
2026-07-03 23:51:45 +02:00
2026-07-03 23:52:02 +02:00
2023-10-17 19:29:06 +02:00
2024-02-19 23:10:10 +01:00
2026-05-25 08:18:12 +04:00
2025-06-22 10:01:36 +02:00
2023-03-02 16:57:32 +03:00
2026-02-04 09:24:14 +01:00
2023-10-17 19:29:06 +02:00
2023-03-02 16:57:32 +03:00
2026-02-04 09:24:14 +01:00
2026-02-04 09:24:14 +01:00
2023-03-02 16:57:32 +03:00